Features

  1. Auto & Manual selection switch.
  2. High pressure pump can be set on 0 to 5 min. delay time. ("0" means no delay times)
  3. Dry run protection for Raw water pump & high pressure pump.
  4. Auto Flusher ON time set (0 to 2.5 min.) and display provided. ("0" means off condition)
  5. 8 function status indicatons.
  6. Maximum pump load up to 3HP.
  7. Auto Restart procedure. (Restart after 15 sec.)

Specifications

  • Model - MC101, MC101H
  • I/P Voltage - 230VAC, (170VAC - 280 VAC) 1∅, 50Hz
  • R/W pump- 230VAC, 3HP (1∅) Max.
  • High pressure pump - 230V AC, 3HP (1∅) Max
  • Dosing pump - 230VAC, 1HP (1∅) Max.
  • Auto Flusher - 230VAC
  • Low pressure protection (total system off)
  • High pressure protection (total system off)
  • Mounting - Panel mounting / Table top
  • Dimension - L 150 X W 135 X H 80 mm.
  • Cutout Dimension - W 115 X H 80 mm.
  • Operating Environment - 0 to 60°c
  • Gross Weight - 1 kg. (approx)
  • Suitable for 500 to 1000 ltr.